LY-DOAS Ultra-low Concentration UV-DOAS Gas Measurement Optical Module (Portable Type)

Module Introduction

Based on the Standard Type, the portable type Ultra-low Concentration UV-DOAS Gas Measurement Optical Module reduces the volume of spectrometer and cancels the optical fiber, which makes the module more integrated and compact, and is more suitable for the development of portable instruments.

Principle

When the UV-Vis light of continuous spectrum passes through the target gas- in the gas cell, light of specific wavelength will be absorbed by the Target gas. The absorption (absorbance) of light is proportional to the concentration of the target gas. An empirical relation curve between the laboratory calibrated absorbance and the concentration of the sample gas is established by spectral analysis and chemometrics methods, then the concentration of the target gas can be calculated in real time according to the absorbance of the sample gas.  

LYDOAS UV-DOAS gas measurement module adopts a new type of multi-reflection gas chamber designed by LaoYing. After multiple reflections by the concave reflector in the gas chamber, the incident light finally converges to the light outlet. Since the light beam is reflected by reflectors fixed at both ends of the gas chamber the chamber wall is not involved in the light reflection, thus avoiding signal drift, sensitivity loss, etc. caused by aging of the gas chamber with traditional inner wall and ensuring the optical path stability in long-term use. The multi-reflection technique can achieve both small size and long optical path at the same time, and the optical path can be customized according to application requirements.



 

Features
  • Adopt the UV-DOAS to measure the concentrations of SO2, NO, NO2 and other gases in real time, with no interference from water vapor or dust;
  • Adopt our independently developed deep ultraviolet spectrometer to optimize the ultraviolet spectral response performance;
  • Long service life and short warm-up time by using a low power consumption pulse xenon lamp as the light source.
  • Low power consumption,long service life and short warm-up time by using a pulse xenon lamp as the light source.
  • Constant temperature control of the gas chamber enables stronger environmental adaptability and ensures the accuracy and stability of measurement results;
  • Measuring NO2 directly , with no need of a reformer;
  • The measuring range can be customized;
  • The mechanical structure and specifications according to customer application requirements.
Applications
  • Ambient air analysis

  • Indoor air quality monitoring

  • Analysis of waste gas from pollution sources

  • Analysis of emission from mobile pollution Sources

  • Industrial gas analysis

  • Process measurement technology

Technical Indicators

 

Technical Indicators

Technical Parameters

Measured gas

SO2

NO

NO2

Measuring range

0-300mg/m3

0-150mg/m3

0-200mg/m3

Customizable according to user requirements

Indication error

≤±2% FS

Detection limit

≤1mg/m3

Repeatability

≤1% FS

Zero drift

≤±2% FS /24h

Measuring range drift

≤±2% FS /24h

Response time

T90 < 30 s@1L/min

Operating temperature

(0-40)℃

Relative humidity

≤95%RH

Calibration

Zero - calibration and spancalibration

Communication interface

RS232/RS485

Output signal

Concentration/Original AD value

Communication interface

DC12V/24V

Power

<80W(During warm-up);<15W(Stable operation)

dimensions

300mm×100mm×100mm

Weight

<1Kg

 

Note: The concentration in the table is the mass concentration under the standard state (temperature 273.15 K, pressure 101.325 kPa).

Explanation

The above parameters are totally up to the requirements of the relevant national standards. If product upgrades, or image does not match with real machine, please refer to the real machine.